Page 744 - Foton Workshop Manual - Tunland (AT)
P. 744

04-598                     DIAGNOSTICS - AUTOMATIC TRANSMISSION


           (b)    Disconnect reversing lamp relay R02.

                                                      (c)    Examine reversing lamp relay R02 with a
                                                             multimeter.

                                                             Standard resistance:
      04
                                                        Conditions         Multimeter        Specified
                                                                          connection            value
                                                                               pin

                                                          Normalcy             1-2           Breakover
                                                          Normalcy             3-5            ≥ 1MΩ

                                                         To impose
                                                           voltage
                                                                               3-5             < 2Ω
                                                       between pin 1
                                                            and 2



           Check if the result is normal?
           YES> To step 4.

           NO> Replace reversing lamp relay .

           4 .    Detect open circuit of wiring harness
           (a)    Ignition switch: "LOCK".
           (b)    Disconnect reversing lamp relay R02.
           (c)    Disconnect TCU connector P01 .

                                                      (d)    Examine resistance value between reversing
                                                             lamp relay R02 and TCU P01;
                                                             Standard resistance: (Check for open
                                                             circuit)

                                                       Multimeter connection          Standard value
                                                                 pin

                                                          R02(1) - P001(15)               ≤ 2 Ω

                                                          R02(2) - P001(7)                ≤ 2 Ω








           Check if the result is normal?
           YES>Replace the transmission
           NO>Fix or change the harness.










                                                                                                         Page 744