04-598 DIAGNOSTICS - AUTOMATIC TRANSMISSION
(b) Disconnect reversing lamp relay R02.
(c) Examine reversing lamp relay R02 with a
multimeter.
Standard resistance:
04
Conditions Multimeter Specified
connection value
pin
Normalcy 1-2 Breakover
Normalcy 3-5 ≥ 1MΩ
To impose
voltage
3-5 < 2Ω
between pin 1
and 2
Check if the result is normal?
YES> To step 4.
NO> Replace reversing lamp relay .
4 . Detect open circuit of wiring harness
(a) Ignition switch: "LOCK".
(b) Disconnect reversing lamp relay R02.
(c) Disconnect TCU connector P01 .
(d) Examine resistance value between reversing
lamp relay R02 and TCU P01;
Standard resistance: (Check for open
circuit)
Multimeter connection Standard value
pin
R02(1) - P001(15) ≤ 2 Ω
R02(2) - P001(7) ≤ 2 Ω
Check if the result is normal?
YES>Replace the transmission
NO>Fix or change the harness.
Page 744