04-790                     DIAGNOSTICS - AIR CONDITIONING SYSTEM

           Check whether the result is normal?

           Yes> go to step 3
           No > Maintenance or replace harness.

           3 .    Check temperature regulation servo motor

      04     (a)  Ignition switch: "OFF".
           (b)    Disconnect the connector C031 of temperature regulation servo motor.


                                                      (a)    Check the connector C031 function of the
                                                             temperature regulation servo motor.

                                                        Conditions        Connection         Specified
                                                                              pins              value

                                                        Apply battery     battery (+)-5
                                                                                            temperature
                                                           voltage
                                                       between pins 5     battery (-)-6   regulation servo
                                                                                          motor operation
                                                            and 6










           Check whether the result is normal?

           Yes > Replace the air conditioner controller.
           No > Replace the temperature regulation servo motor, and verify again whether the
           failure exists.