Page 939 - Foton Workshop Manual - Tunland (AT)
P. 939

DIAGNOSTICS - AIR CONDITIONING SYSTEM                        04-793

                 Check whether the result is normal?

                 Yes> go to step 3
                 No > Maintenance or replace harness.

                 3 .    Check the cycle servo motor
                 (a)    Ignition switch: "OFF".                                                                      04
                 (b)    Disconnect the connector C023 of cycle servo motor.


                                                           (c)    Check the connector C023 function of the
                                                                  cycle servo motor.

                                                              Conditions        Connection         Specified
                                                                                    pins             value

                                                             Apply battery      battery (+)-5
                                                                 voltage                          cycle servo
                                                            between pins 5      battery (-)-6   motor operation
                                                                 and 6










                 Check whether the result is normal?

                 Yes > Replace the air conditioner controller.
                 No > Replace the cycle servo motor, and verify again whether the failure exists.