Page 2092 - Foton Workshop Manual - Sauvana
P. 2092
62-40 DIAGNOSIS-POWER WINDOW
(b). Measure the resistance between the
grounding and the No.B7 & No. B8 pin of
the connector C55 on the body controller
with the multimeter.
Standard resistance: (check whether there
is a short circuit)
Connect the pin by Standard value
multimeter
C55 (B7) - Grounding > 1 MΩ
C55 (B8) - Grounding > 1 MΩ
Is the result normal?
Yes>To step 3.
No >Replace the circuit between fuse F13(30A) and No.B7 pin of body controller C55
connector which is a short circuit to ground.
3. Check the body controller power supply
(a). Disconnect the body controller connector
C 5 5 .
(b). Measure the voltage between No.B7 and
No.B8 pin of body controller connector C55
and the grounding with the multimeter.
Standard Voltage:
Connect the pin by Standard value
multimeter
C55 (B7) - Grounding Battery volt
C55 (B8) - Grounding Battery volt
Page 2092