62-42                             DIAGNOSIS-POWER WINDOW


                                                      (c).    Use a multimeter to measure the resistance
                                                              between No. A7, A8, A9, A10, A11, A12 pin
                                                              of BCM control unit connector C54 and the
                                                              grounding.
                                                              Standard resistance: (check whether there
                                                              is a short circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter
                                                               C54 (A7) - Grounding         > 1 MΩ

                                                               C54 (A8) - Grounding         > 1 MΩ

                                                               C54 (A9) - Grounding         > 1 MΩ
                                                               C54 (A10) - Grounding        > 1 MΩ
                                                               C54 (A11) - Grounding        > 1 MΩ

                                                               C54 (A12) - Grounding        > 1 MΩ



                                                      (d).    Disconnect the BCM control unit connector
                                                              C55.























                                                      (e).    No.B9 & No.B10 pins of body controller
                                                              connector C55 and the grounding with a
                                                              multimeter.
                                                              Standard resistance: (check whether there
                                                              is a short circuit)

                                                                Connect the pin by      Standard value
                                                                    multimeter

                                                                C55 (B9) - Grounding        > 1 MΩ
                                                               C55 (B10) - Grounding        > 1 MΩ