Page 2094 - Foton Workshop Manual - Sauvana
P. 2094
62-42 DIAGNOSIS-POWER WINDOW
(c). Use a multimeter to measure the resistance
between No. A7, A8, A9, A10, A11, A12 pin
of BCM control unit connector C54 and the
grounding.
Standard resistance: (check whether there
is a short circuit)
Connect the pin by Standard value
multimeter
C54 (A7) - Grounding > 1 MΩ
C54 (A8) - Grounding > 1 MΩ
C54 (A9) - Grounding > 1 MΩ
C54 (A10) - Grounding > 1 MΩ
C54 (A11) - Grounding > 1 MΩ
C54 (A12) - Grounding > 1 MΩ
(d). Disconnect the BCM control unit connector
C55.
(e). No.B9 & No.B10 pins of body controller
connector C55 and the grounding with a
multimeter.
Standard resistance: (check whether there
is a short circuit)
Connect the pin by Standard value
multimeter
C55 (B9) - Grounding > 1 MΩ
C55 (B10) - Grounding > 1 MΩ
Page 2094