Page 802 - Foton Workshop Manual - Sauvana
P. 802
18A-2 START AND CHARGING - START AND CHARGE SYSTEM
TABLE OF MALFUNCTION SYMPTOMS
The table below can help you to rapidly find out the required malfunction information.
Malfunction Possible Cause Reference
Symptoms
Starter switch control circuit Check circuit to assure reliable connection
(Open)
Starter out-of- Brush and rectifier (Poor Chapter 18 Starting & Charging-generator,
operation connection) overhaul
Starter inside circuit (Open or Chapter 18 Starting & Charging-generator,
short) overhaul
Chapter 18 Starting & Charging - battery, use and
Battery (Low voltage)
maintenance
Starter wire (Poor connection) Check circuit to assure reliable connection
Starter Rectifier (Surface damage or Chapter 18 Starting & Charging-generator,
losspower, can stains) overhaul
not srart engine Brush (Wear) or Brush spring Chapter 18 Starting & Charging-generator,
(Loss elastic force) overhaul
Brush (Wear) or Brush spring Chapter 18 Starting & Charging-generator,
(Loss elastic force) overhaul
Bearing (Wear), commutator Chapter 18 Starting & Charging-generator,
(Wipe shell) overhaul
Engine has
started and Starter relay (Copper contacts Chapter 18 Starting & Charging-generator,
starter continues bond) overhaul
to rotate and Starter commutator (Bend or Chapter 18 Starting & Charging-generator,
produce harsh break) overhaul
noise
Starter gear tooth surface Chapter 18 Starting & Charging-generator,
contact (Roughening or stuck) overhaul
Generator connect wire Check circuit to assure reliable connection
Chapter 18 Starting & Charging-generator,
Rotor coil (Open)
overhaul
Chapter 18 Starting & Charging-generator,
Generator out- Rectifier diode (Damaged) overhaul
of-operation
Chapter 18 Starting & Charging-generator,
Brush (Poor connection)
overhaul
Chapter 18 Starting & Charging-generator,
Regulator (Damaged)
overhaul
Page 802