START AND CHARGING - GENERATOR 18A-7
(g). Remove and inspect rotor.
•Check whether the rotor coil is
conductive, and confirm that the collector
rings are conductive. Measure the
resistance of rotor. If the resistance is
less than the specified value, it means
the rotor is a short circuit. If it is not
conductive or it is a short circuit, replace
fuwx18A009
the rotor assembly.
Standard: 3~5Ω
• Check the rotor coil ground. Confirm that
it is insulative between collector ring and
core. If not insulative, replace the rotor
assembly.
fuwx18A010
• Using a vernier caliper, measure the slip 18A
ring diameter.
Standard: 14.2~14.4 mm
Limit: 12.8 mm
fuwx18A011
(h). Remove and inspect stator.
• Check the stator for continuity. Confirm
whether the coil lead is conductive. If not
conductive, replace the stator assembly.
Standard: 5~6Ω