Page 804 - Foton Workshop Manual - Sauvana
P. 804

18A-4                         START AND CHARGING - GENERATOR

           GENERATOR


           OVERHAUL


           1.     Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
                  Charging - Battery, Replacement")
           2.     Cool the engine, make the belt temperature close to the normal temperature
           3.     Rotate the generator belt and check for crack


                                                      4.      Remove the  generator
                                                       (a).   Unscrew  the  supporting  bolts  of  the
                                                              generator.
                                                       (b).   Remove the drive belt.







                                           fuwx18A002

                                                      (c).    Unscrew the nuts of the generator
                                                              terminals and remove the harness.
                                                       (d).   Disconnect the connector of the generator.









                                           fuwx18A003

                                                      (e).    Unscrew  the  supporting  bolts  of  the
                                                              generator and remove the generator.











                                           fuwx18A002





















                                                                                                      Page 804