Page 804 - Foton Workshop Manual - Sauvana
P. 804
18A-4 START AND CHARGING - GENERATOR
GENERATOR
OVERHAUL
1. Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
Charging - Battery, Replacement")
2. Cool the engine, make the belt temperature close to the normal temperature
3. Rotate the generator belt and check for crack
4. Remove the generator
(a). Unscrew the supporting bolts of the
generator.
(b). Remove the drive belt.
fuwx18A002
(c). Unscrew the nuts of the generator
terminals and remove the harness.
(d). Disconnect the connector of the generator.
fuwx18A003
(e). Unscrew the supporting bolts of the
generator and remove the generator.
fuwx18A002
Page 804