Page 186 - Workshop Manual - Tunland (2017)
P. 186
04-48 DIAGNOSTICS - SRS SYSTEM
(a) Disconnect SRS control module connector
C016.
04
(b) Measure the resistance between SRS control
module connector C016 and clock spring
Connector C010.
Standard voltage
Multimeter connection Standard value
C016(10) - C010(1)
< 2 Ω
C016(11) - C010(2)
Check whether the result is normal?
Yes> Replace Driver’s SRS assembly, and use diagnostic unit to remove diagnostic
defect code; if the defect code is not removed, replace SRS control module.
No > Maintenance or replace harness.