Page 186 - Workshop Manual - Tunland (2017)
P. 186

04-48                             DIAGNOSTICS - SRS SYSTEM

                                                      (a)    Disconnect SRS control module connector
                                                             C016.







      04














                                                      (b)    Measure the resistance between SRS control
                                                             module connector C016 and clock spring
                                                             Connector C010.
                                                             Standard voltage

                                                       Multimeter connection          Standard value

                                                         C016(10) - C010(1)
                                                                                          < 2 Ω
                                                         C016(11) - C010(2)



















           Check whether the result is normal?

           Yes> Replace Driver’s SRS assembly, and use diagnostic unit to remove diagnostic
           defect code; if the defect code is not removed, replace SRS control module.
           No > Maintenance or replace harness.