Page 189 - Workshop Manual - Tunland (2017)
P. 189

DIAGNOSTICS - SRS SYSTEM                                04-51

                                                           (e)    Check the resistance between clock spring
                                                                  socket C010 and driver’s SRS assembly
                                                                  connector.
                                                                  Standard resistance (check whether there
                                                                  is short circuit)

                                                                                                                     04
                                                            Multimeter connection          Standard value
                                                                C010 (1) ground
                                                                                               ≥ 1 MΩ
                                                                C010 (2) ground









                 Check whether the result is normal?
                 Yes> go to step 2
                 No> Replace the clock spring


                 2 .    Check the harness (SRS control module-clock spring)

                                                           (a)    Disconnect SRS control module connector