04-54                             DIAGNOSTICS - SRS SYSTEM

           Diagnostic steps

           1 .    Check harness (SRS control module-lock spring)

           (a)    Turn off the ignition switch, and disconnect the negative pole of the battery for more
                  than 90 seconds.


      04                                              (b)    Dismantle horn button assembly and
                                                             disconnect the driver's SRS assembly
                                                             connector.
















                                                      (c)    Disconnect SRS control module connector
                                                             C016.
                                                      (d)    Disconnect the connector of clock spring
                                                             C010.
                                                      (e)    Connect the negative pole of the battery and
                                                             turn on ignition switch to “ON”.















                                                      (f)    Disconnect the connector of clock spring
                                                             C010.
                                                             Standard voltage

                                                       Multimeter connection          Standard value

                                                          C010 (1) ground
                                                                                             0V
                                                          C010 (2) ground












           Check whether the result is normal?
           Yes> go to step 2