Page 246 - Workshop Manual - Tunland (2017)
P. 246

04-108                          DIAGNOSTICS - TRANSFER GEAR

           Diagnostic steps

           1 .    Check fuse

           (a)    Ignition Switch: ON.
           (b)    Check whether the fuse of fuse box: F11(60A), F36(10A) is fusing or not.
                  Check whether the result is normal?
      04
                  Yes> go to step 2

                  No> replace fuse

           2 .    Check mode select switch C039 power supply circuit.

                                                      (a)    Ignition Switch: ON.
                                                      (b)    Disconnect mode select switch connector
                                                             C039.
                                                      (c)    Use multimeter to measure the voltage
                                                             between pin 9 of mode select switch C039
                                                             connector and the ground connection.
                                       C039
                                                       Multimeter connection          Standard value

                                                          C039 (9) - ground           Battery voltage






                                            ftwxd041358


           Check whether the result is normal?
           Yes> go to step 3
           No> if there is no battery voltage at pin 9 of C039 connector of mode select switch,
           repair the open circuit between Fuse F36 (10A) and pin 9 of C039 connector of the
           mode select switch.


           3 .    Check the power supply ground connection of mode select switch

                                                      (a)    Ignition Switch: OFF.
                                                      (b)    Use multimeter to measure the voltage
                                                             between pin 8 of C039 connector of mode
                                                             select switch and the ground connection.

                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)
                                       C039
                                                       Multimeter connection          Standard value

                                                          C039 (8)- ground                ≤ 2 Ω






                                            ftwxd041359
   241   242   243   244   245   246   247   248   249   250   251