Page 286 - Workshop Manual - Tunland (2017)
P. 286
04-148 DIAGNOSTICS - POWER WINDOW
(b) Use multimeter to measure the resistance
between No.B7 stitch of connector C033 of
the body and the ground.
Standard resistance (check whether there
is short circuit)
04 Multimeter connection Standard value
C033 (B7)-ground >1 MΩ
Check whether the result is normal?
Yes> replace body controller
No> replace fuse: F13 (30A), repair to-ground short circuit between fuse F13(30A) and
No.B8 stitch of connector C033 of body controller
3 . Check power supply circuit of body controller
(a) Use multimeter to measure the resistance
between No.B8 stitch of connector C033 of
body controller and the ground.
Standard resistance (check whether there
is short circuit)
Multimeter connection Standard value
C033 (B8)- ground >1 MΩ
Check whether the result is normal?
Yes> go to step 4.
No> replace fuse: F14 (30A), repair to-ground short circuit between fuse F14 (30A) and
pin B8 of connector C033 of body controller
4 . Check power supply circuit of body controller