Page 288 - Workshop Manual - Tunland (2017)
P. 288

04-150                          DIAGNOSTICS - POWER WINDOW

                                                      (b)    Use multimeter to measure the resistance
                                                             between stitches B11, B12 of connector C033
                                                             of the body controller and ground.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

      04                                               Multimeter connection          Standard value

                                                         C033 (B11) -ground               < 2 Ω
                                                         C033 (B12) -ground               < 2 Ω









           Check whether the result is normal?
           Yes> go to step 6.
           No> Repair the open circuit between stitches B11, B12 of connector C033 of the body
           controller and ground


           6 .    Check assembly circuit of power lifter
           (a)    Ignition Switch: OFF.

                                                      (b)    Disconnect motor connector J002, left front
                                                             power window
                                                      (c)    Disconnect motor connector I004, left rear
                                                             power window
                                                      (d)    Disconnect motor connector G001, right front
                                                             power window
                                                      (e)    Disconnect motor connector H004, left rear
                                                             power window






                                                      (f)    Use multimeter to measure the resistance
                                                             between stitches A7, A8, A9, A10, A11, A12
                                                             of connector C033 of body controller and the
                                                             ground.
                                                             Standard resistance (check whether there
                                                             is short circuit)

                                                       Multimeter connection          Standard value

                                                         C032 (A7)- ground                < 2 Ω
                                                          C032(A8) -ground                < 2 Ω

                                                         C032 (A9)- ground                < 2 Ω

                                                         C032 (A10)- ground               < 2 Ω