Page 288 - Workshop Manual - Tunland (2017)
P. 288
04-150 DIAGNOSTICS - POWER WINDOW
(b) Use multimeter to measure the resistance
between stitches B11, B12 of connector C033
of the body controller and ground.
Standard electrical resistance (check
whether there existent an open circuit)
04 Multimeter connection Standard value
C033 (B11) -ground < 2 Ω
C033 (B12) -ground < 2 Ω
Check whether the result is normal?
Yes> go to step 6.
No> Repair the open circuit between stitches B11, B12 of connector C033 of the body
controller and ground
6 . Check assembly circuit of power lifter
(a) Ignition Switch: OFF.
(b) Disconnect motor connector J002, left front
power window
(c) Disconnect motor connector I004, left rear
power window
(d) Disconnect motor connector G001, right front
power window
(e) Disconnect motor connector H004, left rear
power window
(f) Use multimeter to measure the resistance
between stitches A7, A8, A9, A10, A11, A12
of connector C033 of body controller and the
ground.
Standard resistance (check whether there
is short circuit)
Multimeter connection Standard value
C032 (A7)- ground < 2 Ω
C032(A8) -ground < 2 Ω
C032 (A9)- ground < 2 Ω
C032 (A10)- ground < 2 Ω