Page 455 - Workshop Manual - Tunland (2017)
P. 455

DIAGNOSTICS - AIR CONDITIONING SYSTEM                        04-317

                                                           (d)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                                                                                     04
                                                            C021(B4)-C014(1)

                                                            C021(A7)-C014(2)
                                                            C021(A4)-C014(3)
                                                                                                 <2Ω
                                                              C021(A13)-C014
                                                                      (5)

                                                              C021(B13)-C014
                                                                      (6)






                 Check whether the result is normal?

                 Yes> go to step 3
                 No > Maintenance or replace harness.

                 3 .    Check the mode air door servo motor

                 (a)    Ignition switch: "OFF".
                 (b)    Disconnect the connector C014 of the mode air door servo motor.

                                                           (c)    Check the function of mode air door servo
                                                                  motor C014.

                                                              Conditions        Connection         Specified
                                                                                    pins             value

                                                             Apply battery      battery (+)-5
                                                                                                 mode air door
                                                                 voltage
                                                            between pins 5      battery (-)-6     servo motor
                                                                 and 6                             operation










                 Check whether the result is normal?

                 Yes > Replace the air conditioner controller.
                 No > Replace the mode air door servo motor, and verify again whether the failure
                 exists.
   450   451   452   453   454   455   456   457   458   459   460