Page 460 - Workshop Manual - Tunland (2017)
P. 460

04-322                     DIAGNOSTICS - AIR CONDITIONING SYSTEM


           2 .    Check the harness and connectors (air condition controller - cycle servo motor)
           (a)    Disconnect battery negative cable.


                                                      (b)    Disconnect the connector C021 of air
                                                             conditioner controller.

      04




















                                                      (c)    Disconnect the cycle servo motor C023.
























                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)


                                                       Multimeter connection          Standard value
                                                       C021(B4)-C023(1)

                                                       C021(B7-C023(2)

                                                       C021(A4)-C023(3)
                                                                                           <2Ω
                                                         C021(A11)-C023
                                                                (5)


                                                         C021(B11)-C023
                                                                (6)
   455   456   457   458   459   460   461   462   463   464   465