Page 458 - Workshop Manual - Tunland (2017)
P. 458
04-320 DIAGNOSTICS - AIR CONDITIONING SYSTEM
(d) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
04
C021(B4)-C031(1)
C021(A8)-C031(2)
C021(A4)-C031(3)
<2Ω
C021(12)-C031(5)
C021(B12)-C031
(6)
Check whether the result is normal?
Yes> go to step 3
No > Maintenance or replace harness.
3 . Check temperature regulation servo motor
(a) Ignition switch: "OFF".
(b) Disconnect the connector C031 of temperature regulation servo motor.
(a) Check the connector C031 function of the
temperature regulation servo motor.
Conditions Connection Specified
pins value
Apply battery battery (+)-5
temperature
voltage
between pins 5 battery (-)-6 regulation servo
and 6 motor operation
Check whether the result is normal?
Yes > Replace the air conditioner controller.
No > Replace the temperature regulation servo motor, and verify again whether the
failure exists.