Page 619 - Workshop Manual - Tunland (2017)
P. 619
DIAGNOSTICS - ASSEMBLY INSTRUMENT 04-481
(b) Disconnect the connector C013 of
combination instrument.
04
ftwx831083
(c) Use a multimeter to measure the resistance
between pin 1 of connector C013 of
combination instrument and the ground.
C013
Standard resistance (check whether there
is short circuit)
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
Multimeter connection Standard value
C013 (1) -ground ≥ 1 MΩ
1
ftwxd041420
(d) Use a multimeter to measure the resistance
between pins 3 of connector C013 of the
combination instrument and the ground.
C013
Standard resistance (check whether there
is short circuit)
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
Multimeter connection Standard value
C013 (3) -ground ≥ 1 MΩ
3
ftwxd041421
Check whether the result is normal?
Yes> replace combination instrument assembly.
No > Repair the to-ground short circuit of the circuit between fuse F26(7.5 A) and
pin 1 of connector C013 of combination instrument; Repair the to-ground short circuit