Page 619 - Workshop Manual - Tunland (2017)
P. 619

DIAGNOSTICS - ASSEMBLY INSTRUMENT                           04-481

                                                           (b)    Disconnect the connector C013 of
                                                                  combination instrument.







                                                                                                                     04










                                                 ftwx831083


                                                           (c)    Use a multimeter to measure the resistance
                                                                  between pin 1 of connector C013 of
                                                                  combination instrument and the ground.
                                                   C013
                                                                  Standard resistance (check whether there
                                                                  is short circuit)
                            16 15  14  13 12  11 10  9  8  7  6  5  4  3  2  1
                            32 31  30  29 28 27  26  25  24  23  22  21  20  19  18 17
                                                            Multimeter connection          Standard value
                                                                C013 (1) -ground               ≥ 1 MΩ
                               1







                                                 ftwxd041420

                                                           (d)    Use a multimeter to measure the resistance
                                                                  between pins 3 of connector C013 of the
                                                                  combination instrument and the ground.
                                                   C013
                                                                  Standard resistance (check whether there
                                                                  is short circuit)
                            16 15  14  13 12  11 10  9  8  7  6  5  4  3  2  1
                            32 31  30  29 28 27  26  25  24  23  22  21  20  19  18 17
                                                            Multimeter connection          Standard value
                                                                C013 (3) -ground               ≥ 1 MΩ
                               3






                                                 ftwxd041421


                 Check whether the result is normal?
                 Yes> replace combination instrument assembly.

                 No > Repair the to-ground short circuit of the circuit between fuse F26(7.5 A) and
                 pin 1 of connector C013 of combination instrument; Repair the to-ground short circuit
   614   615   616   617   618   619   620   621   622   623   624