Page 783 - Workshop Manual - Tunland (2017)
P. 783

DIAGNOSTICS - ENGINE CONTROL SYSTEM                            04-97

                                                           (f)    Use a multimeter to measure the resistance         04
                                                                  between the pin 85 of main fan relay R16 and
                                                                  the pin 34 of ECM connector A024.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin
                                                            R16(85)- A024(34)                   <10 Ω












                                                           (g)    Use a multimeter to measure the resistance
                                                                  between the pin 85 of auxiliary fan relay R4
                                                                  and the pin 34 of ECM connector A024.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                            R4(85)- A024(34)                    <10 Ω











                                                           (h)    Use a multimeter to measure the resistance
                                                                  between the pin 85 of main fan relay R5 and
                                                                  the ground.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                               R5(85)- ground                 > 10 MΩ
   778   779   780   781   782   783   784   785   786   787   788