Page 788 - Workshop Manual - Tunland (2017)
P. 788
04-102 DIAGNOSTICS - ENGINE CONTROL SYSTEM
04 (v) Use a multimeter to measure the resistance
between the pin 3 of main fan connector A012
and the ground.
Standard resistance
Multimeter connection
Standard value
pin
A013(2)- ground <10 Ω
Is the inspection result normal?
YES>To step 6.
No > Maintain or replace the harness.
6 . Check the fan
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect the main fan connector A012 and the auxiliary fan connector A013.
(d) Check whether the fan is good or not.
Is the inspection result normal?
YES>To step 7.
NO>Replace the fan.
7 . Replace ECM
(a) Replace ECM.
(b) Use a diagnostic apparatus to perform DTC verification procedures.
(c) Implement the steps to read sensor data stream.
(d) Verify that no DTC exists and the data are normal.