Page 788 - Workshop Manual - Tunland (2017)
P. 788

04-102                     DIAGNOSTICS - ENGINE CONTROL SYSTEM

      04                                              (v)    Use a multimeter to measure the resistance
                                                             between the pin 3 of main fan connector A012
                                                             and the ground.
                                                             Standard resistance

                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin
                                                         A013(2)- ground                  <10 Ω












           Is the inspection result normal?
           YES>To step 6.
           No > Maintain or replace the harness.


           6 .    Check the fan
           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect the main fan connector A012 and the auxiliary fan connector A013.
           (d)    Check whether the fan is good or not.
           Is the inspection result normal?

           YES>To step 7.
           NO>Replace the fan.

           7 .    Replace ECM

           (a)    Replace ECM.
           (b)    Use a diagnostic apparatus to perform DTC verification procedures.
           (c)    Implement the steps to read sensor data stream.
           (d)    Verify that no DTC exists and the data are normal.
   783   784   785   786   787   788   789   790   791   792   793