DIAGNOSTICS - ENGINE CONTROL SYSTEM 04-101
(s) Use a multimeter to measure the resistance 04
between the pin 2 of main fan connector A012
and the ground.
Standard resistance
Multimeter connection
Standard value
pin
A012(2)- ground > 10 MΩ
(t) Use a multimeter to measure the resistance
between the pin 1 of auxiliary fan connector
A013 and the ground.
Standard resistance
Multimeter connection
Standard value
pin
A013(1)- ground > 10 MΩ
(u) Use a multimeter to measure the resistance
between the pin 3 of main fan connector A012
and the ground.
Standard resistance
Multimeter connection
Standard value
pin
A012(3)- ground <10 Ω