Page 809 - Workshop Manual - Tunland (2017)
P. 809
DIAGNOSTICS - ENGINE CONTROL SYSTEM 04-123
NO>Intermittent trouble exists. 04
2 . Confirm whether there is fault code related to fuel in fuel indicator sensor?
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect fuel hydrous indicator sensor connector E19
(d) Disconnect connector E01 of ECM.
(e) Use a multimeter to measure the resistance
between the pin 1, 2 of fuel hydrous indicator
sensor connector E19 and the pin 49, 50 of
ECM connector E01 respectively.
Standard resistance
Multimeter connection
Standard value
pin
E19(1)- E01(47) <10 Ω
E19(2)- E01(44) <10 Ω
(f) Use a multimeter to measure the resistance
between the pin 1, 2 of fuel hydrous indicator
sensor connector E19 and the ground
respectively.
Standard resistance
Multimeter connection
Standard value
pin
E19(1)- ground > 10 MΩ
E19(2)- ground > 10 MΩ
Is the inspection result normal?
YES>To step 3.
No > Maintain or replace the harness.
3 . Replace fuel in fuel indicator sensor
(a) Replace fuel in fuel indicator sensor.
(b) Use a diagnostic apparatus to perform DTC verification procedures.
(c) Implement the steps to read sensor data stream.
(d) Check whether DTC exists.
Is the inspection result normal?