DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-125

                 P441,P442,P596,P597-BATTERY AND ELECTRICAL                                                          04

                 CHARGING SYSTEM FAILURE
                 P441-BATTERY 1 VOLTAGE - DATA IS VALID BUT BELOW

                 NORMAL OPERATING RANGE - MEDIUM SEVERITY LEVEL
                 P442-BATTERY 1 VOLTAGE - DATA IS VALID BUT ABOVE
                 NORMAL OPERATING RANGE - MEDIUM SEVERITY LEVEL

                 P596-CHARGING SYSTEM VOLTAGE - DATA IS VALID BUT
                 ABOVE NORMAL OPERATING RANGE - MEDIUM SEVERITY

                 LEVEL
                 P597-CHARGING SYSTEM VOLTAGE - DATA IS VALID BUT
                 BELOW NORMAL OPERATING RANGE - MEDIUM SEVERITY

                 LEVEL
                 P598-CHARGING SYSTEM VOLTAGE - DATA IS VALID BUT

                 BELOW NORMAL OPERATING RANGE - HIGHEST SEVERITY
                 LEVEL

                 Description
                 1 .    The engine control module (ECM) obtains a stable voltage through the switch-free
                        battery guide line connected directly to the battery positive (+) terminal.There
                        is one 30A fuses in the switch-free battery guide line to protect the OEM harness.
                        When the key switch goes to the ON position, the ECM receives the switch
                        controlled battery input via the vehicle key switch wire.The battery loop lead is
                        directly connected to the negative terminal of the battery.

                                                                    DTC inspection
                          DTC                DTC definition                                 Trouble location
                                                                       conditions

                                           Battery 1 voltage -
                                             data is valid but
                          P441                below normal
                                            operating range -                             • attery wiring
                                          medium severity level                             harness or ECM
                                           Battery 1 voltage -    • When the key            connector is in poor
                                             data is valid but      switch is in ON         contact, wiring
                          P442                above normal          position, the           harness is broken
                                            operating range -       diagnosis continues     or shorted
                                          medium severity level     to run                • Generator and its
                                                                                            harness
                                            Charging system
                                          voltage - data is valid                         • ECM
                          P596              but above normal
                                            operating range -
                                          medium severity level
   806   807   808   809   810   811   812   813   814   815   816