Page 944 - Workshop Manual - Tunland (2017)
P. 944

04-258                     DIAGNOSTICS - ENGINE CONTROL SYSTEM

      04
           (b)    Check whether there is a leak inside the EGR valve.
           (c)    Check whether the EGR valve is locked in a closed position.

           Is the inspection result normal?
           YES>To step 3.

           NO>Check the fault location.

           3 .    Check EGR valve circuit
           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect the EGR valve connector E18.
           (d)    Connect the battery negative cable.
           (e)    Ignition switch: ON.

                                                      (f)    Use a multimeter to measure the voltage
                                                             between the pin2, 5 of EGR valve connector
                                                             E18 and the ground respectively.

                                                             Standard voltage
                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin
                                                          E18(2)-ground               Battery voltage

                                                          E18(5)-ground                4.75~5.25 V








           Is the inspection result normal?

           YES>To step 4.
           No > Maintain or replace the harness.

           4 .    Check EGR valve harness

           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect the EGR valve connector E18.
           (d)    Disconnect connector E01 of ECM.
   939   940   941   942   943   944   945   946   947   948   949