Page 51 - AP2464B E-BOOK (KKR2 TOWER)
P. 51
SYSTEM
SPECIFICATION
EQUIPMENT DETAILS / REQUIREMENT
Equipment Specification
1. Toilets - Dual flush toilets are installed
- Handles solid and liquid waste differently
2. Taps - Water saving aerators are installed to reduce the flow
to 2l/min
3. Low flow urinals - Installed to reduce flow to 0.5/flush
4. Grey water collection tank - Sewer system must overflowed by greywater tanks.
Therefore, a drain is needed.
- The tank is opaque to minimize warming potential and
growth of algae
- Equipped with screened air vent to prevent harmful
gas.
5. Greywater treatment - Oil and grease trap included in pretreatment
- Pretreatment include mesh screen to remove hair,
soap and other particles.
- All metal components are made of stainless steel to
protect against corrosion
- All parts firmly installed
6. Pumps - Corrosion resistant to pump the appropriate head to
provide sufficient flow
- Protected from dry running to avoid overheating
- Reduce energy consumption and noise
7. Power supply - Readily accessible but also protect against inadvertent
electricity
8. Controls - A control unit incorporated to ensure effectiveness of
the systems
- Warning system is installed in tanks
9. Sludge holding tank - To avoid septicity, an aerator is supplied to the sludge
holding tank.
10. Drainage, bypass and overflow - The overflow includes avoidance of backflow.
- Overflow and bypass connected to foul drain
- All tanks fitted with overflow to allow discharge of
water.