Page 27 - Eden Meadow 35 houses application as of 12 October
P. 27
LAND TO THE REAR OF EDEN MEADOWS, NEWINGTON
AIR QUALITY ASSESSMENT
Table 5 – Modelled Verification Locations
Height
Site ID Site Type Location X Y
(m)
ZW6 Roadside Newington 3 585861 164817 2.4
96/94 High Street,
SW66 Kerbside 586083 164745 1.9
Newington
SW35 Kerbside 60 High Street, Newington 585961 164779 2.4
High Street, Opp Church
SW42 Kerbside 585936 164788 2.2
Lane
SW19 Kerbside Newington Social Club 585918 164790 2.4
SW20 Kerbside Newington Co Op 585846 164820 2.3
Façade Squirrel Cottage,
SW121 Roadside 587936 164268 1.9
Keycol Hill
31/33 Keycol Hill
SW124 Kerbside 587774 164320 2.0
Sittingbourne Highest Point
DT01 Roadside 60 High Street, Rainham 581568 165952 2.3
Care Home, 117 High Street,
DT16 Roadside 581843 165886 2.5
Rainham
4.24 The following monitoring sites have been removed from the model verification process for the
reasons provided:
• SW45, SW37, SW38, SW36, SW78 – designated kerbside sites. LAQM guidance
states that kerbside sites are generally not recommended for the adjustment of road
traffic modelling results as the inclusion of these sites may lead to an over-adjustment
of modelling at roadside sites. The exception is where kerbside sites are relevant for
exposure, for example properties fronting directly onto the road. In that case, kerbside
sites may be used in the model verification process.
• SW113 – located under a tree canopy. LAQM guidance recommends that diffusion
tubes should be mounted greater than 10m from bushes or trees overhanging or
surrounding the tube location.
• SW130 & SW131 – low data capture rate for 2019.
• DT15 – removed due to proximity to bus stop.
Lustre Consulting Ltd
Report Ref.: 3143/MD/07/2020 Page No. 24