       Appendix 1                                                                                        The recommended Radiation Levels of RF Wireless                      25270-EYAL - 25270_pnim_eyal.1.1 | 6 - A | 18-05-15 | 13:28:56 | SR:-- | Cyan            10
                                                                                                         Communication Equipment specified in this Paragraph must be
               ELECTROMAGNETIC COMPATIBILITY                                                            complied with
               EMC according to IEC 60601-1-2 ed.3
                                                                                                        Guidance and manufacturer’s declaration - electromagnetic emissions
                                                                                                             ®
               Changes or modifications to this product not expressly approved by the             The ProPex  II is intended for use in professional healthcare facility or home
               manufacturer may result in increased emissions or decreased immunity               healthcare electromagnetic environment specified below. The customer or the user or
                                                                                                            ®
               performance of the product and could cause EMC issues with this or                 the ProPex  II should ensure that it is used in such an environment.
               other equipment. This product is designed and tested to comply with                  Emission test   Compliance      Electromagnetic environment - guidance
               applicable regulations regarding EMC and shall be installed and put into
                                                                                                                                            ®
               service according to the EMC information stated as follows.                                                       The ProPex  II uses RF energy only for its
                                                                                                  RF Emissions                   internal function.
                                                                                                  CISPR 11         Group 1       Therefore, its RF emissions are very low and
               Use of portable phones or other radio frequency (RF) emitting                                                     are not likely to cause any interference in                                                                                           11
                                                                                                                                 nearby electronic equipment.
               equipment near the product may cause unexpected or adverse
               operation.                                                                         RF Emissions     Class B
                                                                                                  CISPR 11
               The product must not be used adjacent to, or stacked with, other                   Harmonic
               equipment. If adjacent or stacked use is necessary, the product must               Emissions        Not applicable  The ProPex  II is suitable for use in
                                                                                                                                            ®
               be tested to verify normal operation in the configuration in which it is           IEC 61000-3-2                  professional healthcare facilities or domestic
               being used.                                                                                                       establishments.
                                                                                                  Voltage
                                                                                                  fluctuations/
                                                                                                  flicker emissions   Not applicable