Page 2347 - Cote clinical veterinary advisor dogs and cats 4th
P. 2347

Semen Collection, Cat 1161.e1




            Semen Collection, Cat
  VetBooks.ir


                                               degeneration of sperm after it is outside
           Difficulty level: ♦♦
                                               the body.                            ○   Electroejaculation is performed using
                                                                                      a  rectal  probe  1 cm  in  diameter  and
           Synonym                                                                    12-13 cm long. Lubricate the rectal probe
           Sperm collection                    Possible Complications and             with nonspermicidal lubricant.
                                               Common Errors to Avoid               ○   Insert the probe gently into the rectum
           Overview and Goals                  •  Chemical ejaculation/urethral catheterization  approximately  5-7 cm,  pointing  the
           To safely collect an uncontaminated sample of   ○   Do not advance the catheter further than   electrodes ventrally.
           semen from a male cat                  9 cm into the urethra because you will   ○   Extend the penis manually to clean with
                                                  enter the bladder and the sample will be   gauze moistened with saline.
           Indications                            contaminated.                     ○   Dry the penis.
           •  Artificial insemination           ○   Do not try to pull the sample backward   ○   Place a sterile Eppendorf tube at the tip   Procedures and   Techniques
             ○   Natural  mating  is  impossible  due  to   with a syringe from the catheter; it may   of the penis; do not allow the tip of the
               anatomic,  physiologic,  or  behavioral   reduce the collected sample size.  penis to touch the tube.
               problems                        •  Artificial vagina                 ○   Before  turning  on  the  electroejaculator
             ○   Geographic restrictions        ○   This collection method is not practical in   make sure the amplitude is at zero.
           •  Diagnostic purposes                 the clinical situation because the tomcat   ○   Turn on the electroejaculator.
           •  Research                            needs to be trained, and in most cases, the   ○   Administer  a  series  of  electrical  stimuli
           •  Cryopreservation to retain genetic variation   presence of a queen in heat is necessary.  by turning the dial to the desired voltage
             in many breeds of cats             ○   Not all male cats allow this procedure.  for 2-3 seconds and then abruptly back
           •  To prevent extinction of exotic and endan-  •  Electroejaculation       to zero for 2-3 seconds.
             gered feline species               ○   Location  of  the  probe  is  monitored   ○   The following recommendations have been
                                                  throughout the entire collection to prevent   previously published by Johnson (2010)
           Contraindications                      undue stress.                       for applied stimulus for semen collection
           •  Any male cat with                 ○   Can be considered ethically questionable   in the cat:
             ○   The inability to handle general anesthesia/  and  is  therefore  prohibited  in  several   ■   Set one: 10 times with 2 volts, 10 times
               sedation due to age or disease     countries                            with 3 volts, 10 times with 4 volts, rest
             ○   Sexually transmitted diseases  ○   The required equipment is expensive.  for 3-5 minutes.
             ○   Hereditable disorders such as                                        ■   Set two: 10 times with 3 volts, 10 times
                 Deafness                      Procedure                               with 4 volts, 10 times with 5 volts, rest
               ■
                 Hypertrophic cardiomyopathy   •  Chemical ejaculation/urethral catheterization  for 3-5 minutes.
               ■
                 Manx syndrome                  ○   Tomcats are intramuscularly injected with     Set  three:  10  times  with  4  volts,  10
               ■                                                                      ■
                 Polycystic kidney disease        medetomidine (130-140 mcg/kg of body   times  with  5  volts,  10  times  with  5
               ■
                 Amyloidosis                      weight).                             volts  (or  6  if  needed,  depending  on
               ■
                                                ○   After the pharmacologic effect is obtained,   previous response).
           Equipment, Anesthesia                  a  modified,  open-ended,  3.5-Fr  tomcat   ○   The sample obtained between each elec-
           •  Sedation  or  general  anesthesia  may  be   catheter is passed 9 cm into the urethra   troejaculation set should be evaluated for
             required, depending on the method used.  and then simply removed.        the presence of sperm.
           •  Electroejaculator  with  feline  size–specific   ○   After  the  catheter  is  removed,  attach  a
             rectal  probe  or  artificial  vagina  or  tomcat   syringe that already has air drawn up into   Postprocedure
             catheter, depending on the method used  it to allow the sample to be forced out   •  Administer  anesthetic  reversal  agent,  as
           •  Sterile  Eppendorf  tube  to  collect  semen     into  a  microcentrifuge  tube  for  further   appropriate, immediately after the procedure.
             into                                 processing.                     •  After the collection and evaluation of semen,
           •  Nonspermicidal lubricant         •  Artificial vagina                 depending on proposed use:
                                                ○   Tomcat must be trained to use an artificial   ○   Fresh  semen  should  be  inseminated  as
           Anticipated Time                       vagina.                             soon as possible.
           •  Chemical ejaculation/urethral catheterization  ○   Training  is  best  performed  with  gentle   ○   Chilled semen can be extended and stored
             ○   Will depend on tomcat’s response to drug   handling in the presence of an estrous   for several days at 4°C -5°C.
               induction; may take seconds but can take   female in familiar surroundings.  ○   Frozen  semen  can  be  extended  and
               up to 10 minutes                 ○   Once trained, the male is allowed to   cryopreserved at −196°C indefinitely.
           •  Artificial vagina                   mount a queen, and the artificial vagina
             ○   Most males can be adequately trained to   is held in place over the penis to facilitate   Alternatives and Their Relative
               the artificial vagina in 2-3 weeks.  and collect the ejaculate.    Merits
           •  Electroejaculation                ○   Construction  of  the  artificial  vagina   •  Epididymal collection
             ○   Will depend on tomcat’s response to drug   consists  of  a  2-mL  rubber  bulb-pipette   •  Testicular biopsy
               induction; may take seconds but can take   and a small Eppendorf test tube placed   •  Vaginal lavage postcoital queen
               up to 10 minutes                   in a water bottle at 37°C.
                                               •  Electroejaculation              Pearls
           Preparation: Important               ○   THE TOMCAT MUST BE ANESTHE-   •  The artificial vagina is easily made from a
           Checkpoints                            TIZED.                            2-mL rubber bulb for a Pasteur pipette and
           It is important to make sure that all the   ■   Suggested anesthesia protocol includes   an Eppendorf tube.
           media,  semen,  and  collection  equipment   dexmedetomidine   (30-40 mcg/kg)   ○   To keep the sample at the accurate
           are  prepared  to  receive  the  sample  before   and  ketamine  (3-5 mg/kg)  injected   temperature,  place  the  Eppendorf  tube
           starting the collection due to the rapid   intramuscularly.                in a water bottle at 37°C.

                                                      www.ExpertConsult.com
   2342   2343   2344   2345   2346   2347   2348   2349   2350   2351   2352