Page 74 - Alliance US FULL
P. 74

...CONTINUED                    PAGE 2 OF 3




       HYDRAULIC FLUID/FILTER REPLACEMENT AND INTERVALS




     Boom Pressure            FIGURE 2
     Filter:
     RB31303 - 38m Roll and smaller,
     RB37303 - 38m ZZ
     and larger.
     Proper filter change interval:
     Initially at 100 hours then every
     250 pump hours or once a year,
     whichever comes first.
     (How to change area: see
     figure 2)
     Boom filter is canister style and
     located next to the HAWE valve
     or inboard of the pump frame
     near the front boom support.











     Suction Filter for          FIGURE 3
     Accumulator:
     RB31203 all models
     Proper filter change interval:
     Initially at 100 hours then every
     250 pump hours or once every six
     months, whichever comes first.
     (How to change area:
     see figure 3)
     The accumulator suction filter is
     behind the plastic four-knob cover
     on the left side of the front reservoir
     on dual-tank systems. On single-
     tank systems the filter housing is
     on the backside of the tank in the
     middle.
     Note: Replace filters when any
     major service or pump replacement
     takes place.











          1.888.870.0908                www.allianceconcretepumps.com                1.888.584.7231




                    Alliance Concrete Pumps Inc. will not be held liable for any loss, damage, or injury relating to these procedures.
   69   70   71   72   73   74   75   76   77   78   79