Page 1179 - Flipbook_SolidDesignSoutheast2020
P. 1179

Gravity Metal Detector System—Operator Setup Manual


         1.6  Installation Essentials– continued


            5.  Static
                Static will be present in all application where non‐conductive materials are falling through air. Care should be
                taken to ground all metal components of the detector system (the valve, frame, pipe flanges, etc.). Although
                the product pipe used already has an anti‐static characteristic, use caution when touching the outside or inside
                of the plastic pipe section. Charges can exceed 50,000 volts and can be dangerous. Contact Fortress Technology
                for assistance in reducing or limiting static problems.
            6.   Piping
                Do not load the reject valve by attaching pipe sections to either output port which may result in valve
                distortion and operation problems.  All piping should be supported externally to avoid valve problems.
            7.   Maintenance
                The valve and pipe section should be routinely inspected for wear or excessive product build‐up which may
                affect proper detection and rejection of contaminants.
            8.   Air Controls
                The air controls must be located close to the divert valve in order to maintain maximum response speed.

            9.   Foot Isolation
                Mounting connections should be isolated electrically or firmly fixed with a thread lock.  Loose mounting points
                can cause false rejections.

            10.  Reject Containment System
                The outfeed of the Metal Detector passes to a diverter valve reject mechanism that diverts in two directions.
                Good product proceeds to the next process while contaminated product is diverted by the reject valve to the
                reject port. The reject port should be piped to a containment vessel to isolate all reject product.

         1.7  Mechanical Installation


         The Gravity metal detector’s framing typically has four 10mm diameter mounting holes. Each one must be securely
         bolted and properly grounded to connecting frames, thus eliminating potential intermittent connections. Below is an
         illustration of one of the mounting points:






                                                    Metal Detector

                                                                           Metal Detector
                                                                           Mounting

                                                                                    System Frame




                                                                               System Frame Mounting
                                                                               Hole 10.0 mm Diameter



                                                                               Product Anti‐Static Pipe
                                                                               Chute