Blister Pack In spection
       Sapphire offers a range of blister applications for tablets, gelcaps and capsules. Detectable
       conditions include missing or partial/underweight tablets – such as broken or ‘capped’
       products – underfill capsules including ‘maracas’.

       The programme will measure mass for correct dosage, check if the seal of the blister pack
       is intact and that the patient leaflet is enclosed, as well as detection of foreign bodies in
       the pack.

       Drug Delivery Device Inspection
       Mechanical analysis checks, on both osmotic and conventional insulin pumps, uses high
       resolution imaging to provide over 30 component checks to ensure the correct assembly
       of the device.

       Air Bubble Detection

       Air bubbles in liquids are a big concern in the pharmaceutical industry, especially where
       they interrupt the product flow such as in osmotic pumps.
       Sapphire has developed a cutting edge visual inspection for detecting bubbles in viscous
       liquid, even when housed in metallic tubes.

       Mass Measurement
       Sapphire’s systems can measure the dose level of powdered drugs to a repeatability of
       <0.1mg in dose carriers, including powder inhaler devices, peelable strips, ring carries
       and dosing from pellets.

       Mass measurement is a standard feature with our G180 systems.
       Specialist systems such as the P2plus and P4 have been developed to measure powder
       filled pockets of disc inhalers. The P2plus and P4 are available as standalone machines or
       can be integrated into a wider packaging and inspection machine.

       The G182 x-ray systems operate at very low energy to
       measure and inspect for bubbles in liquids as well as
       provide mechanical assembly and contaminant checks.


       The G182 is a variant of the G180 line of active pixel area sensor inspection systems
       from Sapphire.
       The customization includes both product handling and software interface changes
       to meet the individual specifications of the customer.

       Superior Performance
       —  Low energy x-ray imaging with APS technology.
       —  Measurement of bubbles detected within the device reservoir.
       —  Customised data management to individual requirements.
       —   Certified for use by unclassified personnel in an uncontrolled area to meet customer
         needs.

       Contact for US sales enquiries:


       Robert Scott
       t. (727) 412-1002






       Sapphire SAC
       9505 N. Congress Ave
       Kansas City, MO 64153
       USA
       t.  +1 (630) 288-2600
       e. enquiries@sapphiresac.com                                                              www.sapphiresac.com
   2983   2984   2985   2986   2987   2988   2989   2990   2991   2992   2993