Page 925 - Flipbook_SolidDesignSoutheast2020
P. 925
EI
EASTERN INSTRUMENTS
TYPE I HDM SPECS
TANGENTIAL PLATE
TANGENTIAL GUIDE
BACKPLATE
616.08
PAN WIDTH
24.26 CURVED
MEASUREMENT
PAN
749.30
TYPE I WIDTH PAN GUIDE
29.50 For Meters With
Top View An Enclosure 30.16
Please See Our 2X 1.19 TRANSPORT EYE BOLT
586.74
TANGENTIAL Type II Catalog 292.66 101.60
23.10
WIDTH OPENING 11.52 4.00
21.58 52.83
.85 2.08 9.53
.38
229.55
9.04
742.95
29.25
5.97
.24
537.08
21.14
Front View Side View
Type I – Specifications
Tangential Installation
Type I Width Pan Width Height Weight (SS)
Opening Angle
29.50 in 23.10 in 24.26 in 38.40 in 665 lb 0° In-Line and
HDM-24
749 mm 587 mm 616 mm 975 mm 302 kg Reverse Feed
53.50 in 47.10 in 48.26 in 38.40 in 1064 lb 0° In-Line and
HDM-48
1359 mm 1196 mm 1226 mm 975 mm 483 kg Reverse Feed
77.50 in 71.1 in 72.26 in 38.40 in 1596 lb 0° In-Line and
HDM-72
1969 mm 1806 mm 1835 mm 975 mm 724 kg Reverse Feed
15
Type I Solids Flow Meters