This infrared scan confirms that there is significant leakage at the duct connections. The
                     current building code requires that the duct connections be double sealed to minimize
                                                        such leakage.






































                     Note the moisture staining on the plywood decking. The metal supports are attached to
                        the refrigerant piping and the metal is cooled by the refrigerant. This is causing
                     condensation that is staining the plywood. Mold growth and rot will result. A method
                                should be employed to separate the metal from the refrigerant.