Page 15 - Vibrations-2
P. 15

These may arise from


            • imbalance


            • misalignment


            • gear mesh


            • bearing defects.


        Order analysis is specifically for rotating machinery.


        Looking how frequencies change as the rotational speed

        of the machine changes.


        It resamples raw signals from the time domain into the


        angular domain, aligning the signal with the angular

        position of the machine.


























        There are two large peaks in this power spectrum.

        The first peak at 60 Hz corresponds to the shaft rotational


        speed of a machine.

                                                                             th
        The  second  peak,  which  is  the  4  harmonic  of  the

        rotational  speed,  corresponds  to  the  bearings  of  the

        machine.







                                                           14