Page 16 - Vibrations-2
P. 16

To monitor the health of the bearings  - follow the

          th
        4  harmonic.

                                                                                            th
        As the speed changes downward to 50 Hz, the 4  harmonic

        of the power spectrum shifts downward.



























        The peaks in a power spectrum of a rotating device are all


        related to the fundamental rotational speed of that device.


        So, even if the FFT is able to clearly analyse the data and


        show the power spectrum for the machine, it is not

        capable of easily tracking speed driven harmonics.



        In  order  analysis,  instead  of  taking  the  FFT  of  the  time


        domain data, the signal is first resampled into the angular

        domain.



        Resampling combines the speed measurements taken from


        a  tachometer  on  the  machine  with  the  vibration

        measurements                      and           interpolates                the          vibration


        measurements  into  a  data  point  per  fraction  of  angular

        rotation.




                                                           15