Control Systems                                               172


                                                Technical Support



            Customer Power Requirement Worksheet – Option A Delta 3-Phase Power 240 VAC
            It is the customer’s responsibility to make sure his Hot Runner Mold Application will not exceed the power limitations of the
            DME Hot Runner Control System Main Circuit Breaker. Even though each slot may be rated at 15 amps, all slots CANNOT
            necessarily deliver full power from all zones simultaneously.

                     PHASE A POWER                    PHASE B POWER                   PHASE C POWER
                   ZONE #         WATTAGE           ZONE #         WATTAGE          ZONE #        WATTAGE
                      1                               2                               3
                      4                               5                               6
                      7                               8                               9
                     10                               11                              12
                     13                               14                              15
                     16                               17                              18
                     19                               20                              21
                     22                               23                              24
                     25                               26                              27
                     28                               29                              30
                     31                               32                              33
                     34                               35                              36
                     37                               38                              39
                     40                               41                              42
                     43                               44                              45
                     46                               47                              48
                     49                               50                              51
                     52                               53                              54
                     55                               56                              57
                     58                               59                              60                              Control Systems   |    Technical Support
             TOTAL PHASE A WATTS             TOTAL PHASE B WATTS             TOTAL PHASE C WATTS


             Record Product Breaker          Record Product Breaker             Record Product
             Size Phase Wattage Not          Size Phase Wattage Not            Breaker Size Phase
                  To Exceed                        To Exceed                 Wattage Not To Exceed

            Breaker Wattage Size Table – For Delta 240 VAC 3-Phase Power
                                                 MAXIMUM PHASE WATTS              MAXIMUM PHASE AMPS
                  BREAKER RATING AMPS               EACH PHASE A,B,C                EACH PHASE A,B,C
                                                CANNOT EXCEED THIS VALUE        CANNOT EXCEED THIS VALUE
                         10 AMP                        1,386 WATTS                      5.77 AMPS
                         20 AMP                        2,771 WATTS                     11.55 AMPS
                         30 AMP                        4,157 WATTS                     17.32 AMPS
                         40 AMP                        5,542 WATTS                     23.09 AMPS
                         50 AMP                        6,928 WATTS                     28.87 AMPS
                         63 AMP                        8,729 WATTS                     36.27 AMPS
                         70 AMP                        9,699 WATTS                     40.41 AMPS
                        100 AMP                       13,856 WATTS                     57.74 AMPS


            For 3 Phase Delta Power: TOTAL WATTS =  SquareRoot (3) x VoltsAC x AMPS
                                           MAXIMUM PHASE WATTS = TOTAL WATTS / 3


               U.S. 800-626-6653    Canada 800-387-6600   dme@milacron.com   www.dme.net