PRESSURE VS TEMPERATURE RATING CURVES

               Curves and ratings presented here are average values for reference only. These values can be significantly affected
            by pressure and temperature charactistics of trim materials, stem packing materials or o-ring, and connection type.
            Other options such as extended stuffing box will be required to achieve the maximum temperature rating. See pages
            Tech-2 through Tech-3  for details.
               For extreme pressure/temperature requirements, please contact factory for recommendations.
               To obtain the maximum pressure rating at an elevated temperature, multiply the maximum pressure rating of the item
            in special material at room temperature, by the elevated temperature factor (% of Design Temperature)





                 Hastelloy C276
                                                                         Inconel 600
              100
                                                                       100
               90
              % of Rated Pressure @ Design Temperature  70            % of Rated Pressure @ Design Temperature  70
                                                                       90
               80
                                                                       80

               60
                                                                       60
               50
                                                                       50
               40
                                                                       40
               30
               20
                                                                       20
               10                                                      30
                                                                       10
                0
                    100  200  300  400  500  600  700  800  900 1000 1100 1200  0
                                                                            100  200  300  400  500  600  700  800  900 1000 1100 1200
                    (38) (93) (149) (204)  (260) (315) (371) (426) (482) (537) (593) (649)
                                                                            (38) (93) (149) (204)  (260) (315) (371) (426) (482) (537) (593) (649)
                                   Temperature ˚F
                                           (˚C)                                            Temperature ˚F
                                                                                                   (˚C)
                                                 Inconel 625
                                              100
                                               90
                                             % of Rated Pressure @ Design Temperature  70
                                               80



                                               60
                                               50
                                               40

                                               30
                                               20
                                               10

                                               0
                                                   100  200  300  400  500  600  700  800  900 1000 1100 1200
                                                   (38) (93) (149) (204)  (260) (315) (371) (426) (482) (537) (593) (649)
                                                                  Temperature ˚F
                                                                          (˚C)

                                                                                                                         Tech-09
                                                              Page Tech-6
                     2121 EBCO Drive, Suite 1  •  Erie, PA 16506 USA  •  Ph: (814) 833-4904  •  Fax: (814) 833-2612  •  E-mail: hq@butech-valve.com