Page 122 - Parker - Hydraulic and Lube Filtration Products
P. 122
MPD Series
MPD-2 Element Performance
Efficiency Capacity
PSID BAR
100
Beta Rating Efficiency %
2Q
10000
5Q
10Q 6
2QQ 5Q5Q 20Q
2 2Q
80
5
99.9
1000
1 10Q
10Q0Q
60 4
200
99.5
100 99.0
2 20Q 3
20Q0Q
40
2
20 95.0
20
1
2
50.0
0 0
0 50 100 150 200 250 300
0 4 8 12 16 20
Capacity grams
Micron Size (c)
Results typical from Multi-pass tests run per test standard ISO 16889 @ 80 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
LPM LPM
0 100 200 300 400 500 0 100 200 300 400 500
150 SUS 150 SUS
25 25
Empty Housing
1.5 1.5
20 20
15 1.0 15 1.0
PSID BAR PSID BAR
10 10
02Q
05Q 0.5 0.5
5 5
10Q Empty Housing
20Q
0 0
0.0 0.0
0 30 60 90 120 150 0 30 60 90 120 150
GPM GPM
117