Page 102 - Schroeder - Hydraulic And Lube Filtration
P. 102

KF30            Base-Ported Pressure Fil ter




                        Filter   How to Build a Valid Model Number for a Schroeder KF30:
                       Model      BOX 1  BOX 2  BOX 3  BOX 4  BOX 5  BOX 6  BOX 7  BOX 8  BOX 9  BOX 10
                     Number       KF30 –     –    –     –     –    –     –     –    –
                    Selection    Example: NOTE: Only boxes 8 and 10 may contain more than one option
                                  BOX 1  BOX 2  BOX 3  BOX 4  BOX 5  BOX 6  BOX 7  BOX 8  BOX 9  BOX 10
                     Same Day     KF30 – 1K – Z – 10 –        –    – S –       – D5 –       = KF301KZ10SD5
                      Shipment
                        Model      BOX 1       BOX 2                    BOX 3
                      available    Filter  Number & Size of
                         with      Series     Elements                Media Type
                     GeoSeal ®     KF30     1   K, KK, 27K  Omit =  E Media (Cellulose)
                      See inside
                      back cover            2   K          AS =  Anti-Stat Media (synthetic)
                                                                           ®
                                                                      ®
                      for details.  KFN30    3  K           Z = Excellement  Z-Media  (synthetic)
                                   ((Non-
                                  bypassing:               ZW =  Aqua-Excellement  ZW Media
                                                                         ®
                                  requires ZX              ZX =  Excellement  Z-Media  (High Collapse centertube)
                                                                           ®
                                                                      ®
                                  high collapse
                                   elements)               W =  W Media (water removal)
                                                           M =  Media (reusable metal mesh) N size only
                                              BOX 4                     BOX 5           BOX 6          BOX 7
                                            MIcron Rating            Seal Material   Magnet option    Porting
                                                                                                         1
                                   1  = 1 Micron  (Z, ZW, ZX media)  Omit =  Buna N  Omit  =  None    P = 1  ⁄2" NPTF
                                   3  = 3 Micron  (AS,E, Z, ZW, ZX media)  V =  Viton    M =  Magnet   P32 = 2" NPTF
                                                                          ®
                                   5  = 5 Micron  (AS, Z, ZW, ZX media)                               S = SAE-24
                                  10  = 10 Micron  (AS,E,M, Z, ZW, ZX media)  H =  EPR    inserts (not   F =  1  ⁄2" SAE
                                                                                                         1
                                                                                          available w/
                                  25  = 25 Micron  (E, Z, ZW, ZX media)   =  Skydrol      indicator in   4-bolt flange
                                                                           ®
                                  60  = 60 Micron  (M media)       H.5  compatibility                   Code 61
       NOTES:                     150  = 150 Micron (M media)                             cap)      F32 =  2" SAE
                                  260  = 260 Micron (M media)                                           4-bolt
       Box 2.   Number of elements                                                                      flange Code
            must equal 1                                                                                61
            when using KK or                                                                         O = Subplate
            27K elements.                                                                           B24 = ISO 228
            Replacement element                                                                            G-1  ⁄2"
                                                                                                           1
            part numbers are
            identical to contents
            of Boxes 2, 3, 4 and       BOX 8                          BOX 9                           BOX 10
            5. Double and triple      Options                            ®
            stacking of K-size                                   Dirt Alarm  Options             Additional Options
            elements can be       Omit  =  None               Omit = None                         Omit =  None
            replaced by single      X =  Blocked bypass         D =  Pointer
            KK and 27K elements,                               D5 = Visual pop-up                  N =  No-Element
            respectively. ZW media   50 =  50 psi bypass   Visual                                     Indicator (not
            not available in 27K       setting                 D5C = D5 in cap                        available w/
            length.                 L =  Two  ⁄4" NPTF inlet   D9 = All stainless D5                  KFN30 or
                                         1
                                       & outlet female   Visual   D8 = Visual w/ thermal lockout      housings w/
       Box 5.   H.5 seal designation   test ports   with                                              indicator in
            includes the                           Thermal     D8C = D8 in cap                        cap)
            following: EPR seals,   U =  Series 1215  ⁄16   Lockout
                                             7
            stainless steel wire mesh   UNF Schroeder          MS5 =   Electrical w/ 12 in. 18 gauge 4-conductor cable  G509 =  Dirt Alarm and
            on elements, and light     Check Test Point      MS5LC =  Low current MS5                 drain opposite
            oil coating on housing     installed in cap       MS10 =   Electrical w/ DIN connector (male end only)  standard
            exterior. Viton  is a      (upstream)           MS10LC =  Low current MS10           G588  =  Electric Switch
                      ®
            registered trademark of   UU =   Series 1215  ⁄16   MS11 =   Electrical w/ 12 ft. 4-conductor wire  and drain
                                             7
            DuPont Dow Elastomers.     UNF Schroeder   Electrical  MS12 =    Electrical w/ 5 pin Brad Harrison connector (male end only)  opposite
                 ®
            Skydrol  is a registered   Check Test Point     MS12LC =   Low current MS12               standard
            trade mark of Solutia Inc.  installed in block    MS16 =   Electrical w/ weather-packed sealed connector
                                       (upstream and        MS16LC =  Low current MS16
       Box 7.   For options F & F32, bolt   downstream)     MS17LC =    Electrical w/ 4 pin Brad Harrison male connector
            depth .75" (19 mm).                               MS5T = MS5 (see above) w/ thermal lockout

              For option O, O-rings                          MS5LCT = Low current MS5T
            included; hardware not                 Electrical   MS10T = MS10 (see above) w/ thermal lockout
            included.                               with    MS10LCT = Low current MS10T
                                                   Thermal   MS12T = MS12 (see above) w/ thermal lockout
       Box 8.   X and 50 options are not           Lockout  MS12LCT = Low current MS12T
              available with KFN30.                          MS16T = MS16 (see above) w/ thermal lockout
                                                            MS16LCT = Low current MS16T
       Box 9.   Standard indicator                          MS17LCT = Low current MS17T
            setting for non-                                   MS =   Cam operated switch w/  ⁄2" conduit female connection
                                                                               1
            bypassing model                        Electrical   MS13 =  Supplied w/ threaded connector & light
            is 50 psi unless                        Visual    MS14 =   Supplied w/ 5 pin Brad Harrison connector & light (male end)
            otherwise specified.                   Electrical   MS13DCT =  MS13 (see above), direct current, w/ thermal lockout
                                                    Visual   MS13DCLCT = Low current MS13DCT
       Box 10.   Options N, G509 and                with    MS14DCT =  MS14 (see above), direct current, w/ thermal lockout
             G588 are not available                Thermal
             with KFN30. N option                  Lockout  MS14DCLCT = Low current MS14DCT
             should be used in
             conjunction with
             dirt alarm.
                              100  SCHROEDER INDUSTRIES
   97   98   99   100   101   102   103   104   105   106   107