Page 102 - Schroeder - Hydraulic And Lube Filtration
P. 102
KF30 Base-Ported Pressure Fil ter
Filter How to Build a Valid Model Number for a Schroeder KF30:
Model BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10
Number KF30 – – – – – – – – –
Selection Example: NOTE: Only boxes 8 and 10 may contain more than one option
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10
Same Day KF30 – 1K – Z – 10 – – – S – – D5 – = KF301KZ10SD5
Shipment
Model BOX 1 BOX 2 BOX 3
available Filter Number & Size of
with Series Elements Media Type
GeoSeal ® KF30 1 K, KK, 27K Omit = E Media (Cellulose)
See inside
back cover 2 K AS = Anti-Stat Media (synthetic)
®
®
for details. KFN30 3 K Z = Excellement Z-Media (synthetic)
((Non-
bypassing: ZW = Aqua-Excellement ZW Media
®
requires ZX ZX = Excellement Z-Media (High Collapse centertube)
®
®
high collapse
elements) W = W Media (water removal)
M = Media (reusable metal mesh) N size only
BOX 4 BOX 5 BOX 6 BOX 7
MIcron Rating Seal Material Magnet option Porting
1
1 = 1 Micron (Z, ZW, ZX media) Omit = Buna N Omit = None P = 1 ⁄2" NPTF
3 = 3 Micron (AS,E, Z, ZW, ZX media) V = Viton M = Magnet P32 = 2" NPTF
®
5 = 5 Micron (AS, Z, ZW, ZX media) S = SAE-24
10 = 10 Micron (AS,E,M, Z, ZW, ZX media) H = EPR inserts (not F = 1 ⁄2" SAE
1
available w/
25 = 25 Micron (E, Z, ZW, ZX media) = Skydrol indicator in 4-bolt flange
®
60 = 60 Micron (M media) H.5 compatibility Code 61
NOTES: 150 = 150 Micron (M media) cap) F32 = 2" SAE
260 = 260 Micron (M media) 4-bolt
Box 2. Number of elements flange Code
must equal 1 61
when using KK or O = Subplate
27K elements. B24 = ISO 228
Replacement element G-1 ⁄2"
1
part numbers are
identical to contents
of Boxes 2, 3, 4 and BOX 8 BOX 9 BOX 10
5. Double and triple Options ®
stacking of K-size Dirt Alarm Options Additional Options
elements can be Omit = None Omit = None Omit = None
replaced by single X = Blocked bypass D = Pointer
KK and 27K elements, D5 = Visual pop-up N = No-Element
respectively. ZW media 50 = 50 psi bypass Visual Indicator (not
not available in 27K setting D5C = D5 in cap available w/
length. L = Two ⁄4" NPTF inlet D9 = All stainless D5 KFN30 or
1
& outlet female Visual D8 = Visual w/ thermal lockout housings w/
Box 5. H.5 seal designation test ports with indicator in
includes the Thermal D8C = D8 in cap cap)
following: EPR seals, U = Series 1215 ⁄16 Lockout
7
stainless steel wire mesh UNF Schroeder MS5 = Electrical w/ 12 in. 18 gauge 4-conductor cable G509 = Dirt Alarm and
on elements, and light Check Test Point MS5LC = Low current MS5 drain opposite
oil coating on housing installed in cap MS10 = Electrical w/ DIN connector (male end only) standard
exterior. Viton is a (upstream) MS10LC = Low current MS10 G588 = Electric Switch
®
registered trademark of UU = Series 1215 ⁄16 MS11 = Electrical w/ 12 ft. 4-conductor wire and drain
7
DuPont Dow Elastomers. UNF Schroeder Electrical MS12 = Electrical w/ 5 pin Brad Harrison connector (male end only) opposite
®
Skydrol is a registered Check Test Point MS12LC = Low current MS12 standard
trade mark of Solutia Inc. installed in block MS16 = Electrical w/ weather-packed sealed connector
(upstream and MS16LC = Low current MS16
Box 7. For options F & F32, bolt downstream) MS17LC = Electrical w/ 4 pin Brad Harrison male connector
depth .75" (19 mm). MS5T = MS5 (see above) w/ thermal lockout
For option O, O-rings MS5LCT = Low current MS5T
included; hardware not Electrical MS10T = MS10 (see above) w/ thermal lockout
included. with MS10LCT = Low current MS10T
Thermal MS12T = MS12 (see above) w/ thermal lockout
Box 8. X and 50 options are not Lockout MS12LCT = Low current MS12T
available with KFN30. MS16T = MS16 (see above) w/ thermal lockout
MS16LCT = Low current MS16T
Box 9. Standard indicator MS17LCT = Low current MS17T
setting for non- MS = Cam operated switch w/ ⁄2" conduit female connection
1
bypassing model Electrical MS13 = Supplied w/ threaded connector & light
is 50 psi unless Visual MS14 = Supplied w/ 5 pin Brad Harrison connector & light (male end)
otherwise specified. Electrical MS13DCT = MS13 (see above), direct current, w/ thermal lockout
Visual MS13DCLCT = Low current MS13DCT
Box 10. Options N, G509 and with MS14DCT = MS14 (see above), direct current, w/ thermal lockout
G588 are not available Thermal
with KFN30. N option Lockout MS14DCLCT = Low current MS14DCT
should be used in
conjunction with
dirt alarm.
100 SCHROEDER INDUSTRIES