Metal Tube & Fitting Material Compatibility                                                             Hose
                                                                                                                     A












                                                                                                                       Tubing
                                                                                 Tube Material to Fitting & Material Compatibility  B




                   Tube   Material  Specification  Construction  Condition  Maximum   Hardness  Temperature Range (7)  Application  Seal-Lok™ ORFS    (SAE J1453)  Triple-Lok  ®  37°   Flare (SAE J514)  Ferulok  ®  Flareless   (SAE J514)  Intru-Lok  ®     Flareless  EO/EO-2 Flareless   (ISO 8434-1)



                                                                                                               S
                                                                                 SS B
                                                                               S
                                                                                                               SS
                                                                                       S SS B
                                                                                                           B
                                                                                                  S SS M
                                                                                               M
                                                                                                              B, M    Coiled Air Hose   & Fittings
                                                                      Lube lines,  chemi-
                                            Flexible &
                                                                                                  G   G   G
                Nylon              Extruded  Semi-Rigid     -60° to 200°F   cal process controls  NR  NR NR NR NR NR NR  (2)  (2)  (2)  E  G (2), (9)  C
                                                            -50° to 95°C
                                                                        & air
                Polyethy-  ASTM D-1248  Extruded  Instrument    -80° to 150°F   Instrumentation lines NR  NR NR NR NR NR NR  G   G   G   E  G (2), (9)
                lene                         Grade          -60° to 65°C                          (2)  (2)  (2)
                                            Instrument &
                                                             0° to 140°F
                PVC                Extruded  Laboratory     -20° to 60°C  General purpose   NR  NR NR NR NR NR NR NR NR NR  G  NR
                                                                       laboratory use
                                             Grade
                                                                      Very high temp,
                PTFE               Extruded                 -65° to 400°F   fuel, lube, chemical,  NR  NR NR NR NR NR NR  G   G   G   G  G (2), (9)  Transportation
                                   & Sintered               -55° to 205°C  pharma, food           (2)  (2)  (2)
                                                                                                                     D
                Table U7 – Tube and Fitting Material Compatibility
                Ratings Key:          Fittings Materials Code:
                NR = Not Recommended    S = Steel
                F = Fair            SS = Stainless Steel
                G = Good            B = Brass                                                                          Fittings
                E = Excellent       M = Monel
                                                                                                                     E
               Notes:
               1. For highly corrosive media or service environment, contact the Tube Fittings Division.
               2. Requires different assembly procedure. Contact the Tube Fittings Division.
               3. Low temperature limit for stainless steel Ferulok  fittings is -20°F (-30°C).
                                              ®
               4. For brazing only. Grade 4130 not recommended with Parflange process.
               5. For use with Parflange process only. Not recommended with brazing.
               6. Use depends on specific application. Contact the Tube Fittings Division.
               7. Applies to tube material.                                                                           Tooling, Equipment
               8. Comparable specifications to SAE.                                                                    & Accessories
               9. With metric version of tubing.
               10. Not tested with Parflange. Contact the Tube Fittings Division.
                                                                                                                     F






                                                                                                                       General Technical





                         For detailed ordering information, please consult price list or contact Parflex Division.   G
                  Parker Hannifin Corporation | Parflex Division | Ravenna, Ohio | parker.com/pfd       G-49