Page 182 - Wago_AutomationTechnology_Volume3_2015_US.pdf
P. 182

750-310

   4    CC-Link Fieldbus Coupler

  180   156 Kbaud ... 10 Mbaud; digital and analog signals




                                                                           CC-Link   01  02   Status
                                                                           L RUN   A          voltage supply
                                                                                    C         -System
                                               Fieldbus                    L ERR   B   D      -Power jumper contacts
                                               connection                  SD   24V  0V       Data contacts
                                               D-Sub
                                                                           RD                 Supply
                                                                                              24 V
                                                                                              0 V
                                                                           I/O
                                                                                 +  +
                                                                                              Supply via
                                                                                              power jumper contacts
                                                                                              24 V
                                                                            W  750- 310
                                                                   0  1  2  3  4  5  6  7  8  9
                                               Baud rate                         —  —

                                                                   0  1  2  3  4  5  6  7  8  9   0 V
                                               Address
                                                                      x1        PE PE
                                                                   0  1  2  3  4  5  6  7  8  9
                                               Address
                                                                      x10
                                               Configuration                                   Power jumper contacts
                                               interface


        This buscoupler connects the WAGO-I/O-SYSTEM as a slave to the CC-Link   The local process image is divided into two data zones containing the data
        fieldbus.                                           received and the data to be sent. The process data can be sent via the CC-Link
                                                            fieldbus to the PLC, PC or NC for further processing, and received from the field
        The buscoupler automatically configures, creating a local process image which  via CC-Link.
        may include analog, digital or specialty modules. Analog and specialty
        module data is sent via words and/or bytes, digital data is sent bit by bit.  The data of the analog modules is stored in the process image which is created
                                                            automatically according to the order in which the modules are connected to the
        CC-Link stores the process image in the corresponding Master control (PLC, PC  buscoupler. The bits of the digital modules are sent byte by byte and added to
        or NC).                                             the analog data. If the amount of digital information exceeds 8 bits, the
                                                            buscoupler automatically starts with a new byte.



        Description                  Item No.        Pack.    System Data
                                                     Unit
        CC-Link                      750-310         1        No. of couplers connected to Master  64
                                                              Transmission medium      Shielded Cu cable 2 / 3 x 0.5 mm²
                                                              Max. length of bus line  100 m ... 1200 m
                                                                                       (depends on baud rate/cable)
                                                              Baud rate                156 Kbaud ... 10 Mbaud
                                                              Buscoupler connection    1 x D-Sub 9; socket


        Accessories                  Item No.        Pack.
                                                     Unit
        Miniature WSB Quick marking system
                     plain           248-501         5
                     with marking    see Section 11

        Bus connector with D-Sub male connector;   750-965  1
        9 poles
        Approvals
        Conformity marking        1
        Korea Certification
        r UL 508
        r ANSI/ISA 12.12.01       Class I, Div. 2, Grp. ABCD, T4
        4 TÜV 07 ATEX 554086 X    I M2 Ex d I Mb,
                                  II 3 G Ex nA IIC T4 Gc,
                                  II 3 D Ex tc IIIC T135°C Dc
              Permissible ambient temperature 0 °C ... +60 °C
        IECEx TUN 09.0001 X       Ex d I Mb,
                                  Ex nA IIC T4 Gc,
                                  Ex tc IIIC T135°C Dc
              Permissible ambient temperature 0 °C ... +60 °C