Page 6 - Clippard - Miniature Pneumatic Products:for scientific applications
P. 6

Cleaned for Oxygen Service



                  Clippard’s Oxygen Clean Series
                  All EV, ET, EC and EW series electronic valves are
                  available manufactured and assembled for use in

                  Oxygen-enriched environments for applications
                  that are extremely sensitive to contamination.

                  • Valves are ultrasonically cleaned, assembled,
                     inspected and tested in an enclosed controlled
                     area with a state-of-the-art positive pressure
                     HEPA filtration system
                  • Both organic and inorganic contaminants such
                     as particulate matter and Hydrocarbon oils are
                     removed
                  • No organic sealants, adhesives or lubricants are
                     used in the manufacturing process
                  • Feature FKM (fluorocarbon) seals
                  • Component parts are lubricated with Oxygen-
                     compatible PFPE (perfluoropolyether) grease,
                     as needed for assembly
                  •  Individual testing and inspection is
                     accomplished utilizing compressed Nitrogen
                     and ultraviolet light


                  For more information on the process, visit
                  www.clippard.com/oxygen











                                                             Medical Ventilators
                                                             For patients who need mechanical assistance in order to breathe efficiently,
                                                             ventilators regulate exact adaptation of pressure and flow characteristics to
                                                             suit their specific needs.  Clippard electronic valves allow the device to deliver
                                                             precise, adjustable volumes of oxygen with each breath.  Due to the vital issues
                                                             surrounding reliability,  Clippard engineers pay careful attention to design
                                                             details that will ensure consistent flow and will extend the life of the valve.









   5                                           513-521-4261 • www.clippard.com
   1   2   3   4   5   6   7   8   9   10   11