           Backflow Preventers


           4A/4ALF-500 SERIES  – MODEL PVB 4A/PVBLF 4A            4W/4WLF-500 SERIES – MODEL SVB 4W/SVBLF 4W

                            Bronze body Pressure Vacuum Breaker with              Spill-resistant pressure  Vacuum Breaker
                            internal freeze relief valve and captured             (SVB) is designed to prevent contamination
                            spring cartridge. Features shutoffs with              of potable water due to back-siphonage
                            stainless steel handles and trim.  Vertical           and is ideally suited for indoor and OEM
                            up/horizontal installation approvals. Sizes:          applications  supplied  w/continuous  pressure
                            1/2”-2”. Lead Free available in sizes 3/4” and        where water discharge could cause
                            1” only.                                              problems. Horizontal installation approvals.
                                                                                  Sizes: 1/4” to 1/2” Noryl® body.



           38/38LF SERIES – MODEL AVB1                            40-400 SERIES – MODEL DCAP
                            Atmospheric  Vacuum Breakers provide                  Bronze body Dual Check with Atmospheric
                            economical, lightweight and compact                   Port. Noryl® poppets and stainless steel
                            protection against back-siphonage and low             springs. ASSE and CSA approvals. Sizes:  1/2”
                            hazard cross connections.  Meets ASSE and             and 3/4”.
                            CSA standards; listed with IAMPO.  For hot
                            and cold water service up to 212°F at 125
                            psig for 1” and up to 180°F at 125 psig for
                            1/4”-2”.



           4N/4NLF-300 SERIES – MODEL DUC4N /DUCLF4N              MODEL DUC-4FP
                            Bronze body Dual Check with two captured              Bronze body Dual Check with two captured
                            spring cartridges. ASSE and CSA approved for          spring cartridges. ASSE, CSA approved and
                            residential backflow protection at the water          UL classified for residential fire sprinkler
                            meter. Multiple connection combinations.              systems. Sizes: 1”, 1-1/4”.
                            Sizes: 3/8”-1”.






            DUC 40/DUCLF 40 SERIES                                4C-100 SERIES – MODEL CBBP

                            The Apollo Series DUC 40 Dual Check Valve             ASSE 1022 approved Carbonated Beverage
                            prevents backflow by either backpressure              Backflow Preventer.  Protects against copper
                            or back-siphonage resulting from a cross-             poisoning by preventing carbonated water
                            connection between potable water lines and            from being drawn into copper pipes.  All wetted
                            substances that are objectionable, but not            components are non-toxic, corrosion resistant,
                            health-hazards.                                       and approved for use with potable water.  Suitable
                                                                                  for supply pressures to 150 psig and water
                                                                                  temperatures from 33° to 130°F.  CSA certified to
                                                                                  NSF61 and IAPMO approved.  Sizes: 1/4” and 3/8”.


           38-502 SERIES –  MODEL LFVB                            HBV2 SERIES

                            Lab Faucet  Vacuum Breakers for potable               Apollo’s HBV Hose Connection  Vacuum
                            water backflow protection for lab faucets,            Breakers are designed to prevent cross-
                            community sinks, beauty salons, barber                connection caused by back-siphonage.
                            shops.  ASSE, CSA approved; IAPMO listed.             They consist of a single check valve with
                            Brass body, polished chrome plating,                  atmospheric vacuum breaker vent.  They
                            stainless steel internal parts.  3/8” FNPT            feature a break-away set-screw for tamper-
                            standard; 1/4” optional.  Adapters simplify           proof protection.  They are not suitable for
                            installation.                                         continuous pressure applications.