Page 19 - Linde - HMF/A/V/R-02 Hydraulic motors for closed and open loop operation
P. 19

Functions. Signal selection for pressure regulator


            Pressure regulated motors shift to maximum displacement at high operating pressure, irrespective of which side is under pressure.
            In propel drives this can have undesirable effects. For example, if the motor shifts to maximum displacement during the transition
            phase from straight travel with low system pressure to overrun (deceleration, downhill travel) with high pressure on the reverse
            side, an extremely strong vehicle braking effect will occur. The signal selection for pressure regulator prevents the regulator being
            subjected to this braking pressure and, therefore, ensures that the motor remains at minimum displacement. For equipment options
            for Series 02 motors please refer to the model code.





            Without signal selection                                  With signal selection for
            for pressure regulator                            pressure regulator










































































                                                                                                                 19