Page 18 - Linde - HMF/A/V/R-02 Hydraulic motors for closed and open loop operation
P. 18

Functions. Crossline relief (secondary) protection


            The  secondary  valves  (crossline  relief  valves)  protect  the  system  from  pressure  overload  by  using  two  interlinked  pressure
            relief valves (combined with check valves). It is recommended for applications where this protective function is not provided by
            other means (e.g. through primary protection at the pump or LS valves). The secondary protection includes a make up function.
            It prevents cavitation and is required in an open loop circuit if the motor requires more oil than is supplied. For special situations
            like in the swing gear drive the installation of controllable secondary valves is recommended. For equipment options for Series 02
            motors please refer to the model code.





            Without crossline relief valve                    With crossline relief valve protection























            With dual pressure crossline relief valve protection

                                                              A, B   Work ports
                                                              L, L1, U   Case drain/vent connections
                                                              X, Y   Control connection for dual
                                                                     pressure crossline relief valve
                                                              E      Make up connection








































      18
   13   14   15   16   17   18   19   20   21   22   23