Page 16 - Linde - HMF/A/V/R-02 Hydraulic motors for closed and open loop operation
P. 16

Functions. Purge and case flushing


            Purge and case flushing is used
            >> for reducing the temperature of the motor and the system in the open and closed loop circuits
            >> for replacing the oil in the circuit
            >> to enhance filtration and
            >> for removing air from the system
            For equipment options for Series 02 motors please refer to the model code.




            Purge flow in closed loop circuit

              Version         Purge valve pressure CBV setting  Diagram        Purge Flow    Diameter of orifice


              Standard        10 bar                              3             10 l/min         2.5 mm
                              with 20 bar feed pressure
              Standard        14 bar                              2             10 l/min       without orifice
                              with 20 bar feed pressure
              Restricted      10 bar                              3             5 l/min           2 mm
                              with 20 bar feed pressure
              Restricted      14 bar                              3             5 l/min          2.5 mm
                              with 20 bar feed pressure
              Increased       10 bar                              2             20 l/min       without orifice
                              with 20 bar feed pressure
              Flow controlled  14 bar                             4             4 l/min      with flow regulator
                              with >20 bar feed pressure





            Purge valve 1. Without (0 l/min)                  Purge valve 2. Standard and increased




















            Purge valve 3. Restricted                         Purge valve 4. Flow controlled