Page 106 - Shroeder - Filter Systems
P. 106
X Series X Series Filter Skids SMART ™
TECHNOLOGY INSIDE
Model Number How to Build a Valid Model Number for a Schroeder X Series Filter Skid:
Selection BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11 BOX 12 BOX 13
X1 – – – – – – – – – – – –
Example: NOTE: One option per box
NOTES:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11 BOX 12 BOX 13
Box 1.
Z1 media not offered X1 – 17 – 2K – B – B – B – N – N – A – G – N – S – N = X1172KBBBNNAGNSN
for use in 500 to 2000
SUS filtration skids.
Contact factory for BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6
specific applications.
(X2, X5) Z1 and Z3 Flow Filter Designation Element Media Element Media Seal
QF15 Filter
media not offered for Model (gpm) K9 Filter 1st Filter 2nd Filter Material
use in 2000 to 5000 1K 2K 3K 16Q 39Q
SUS filtration skids. 17 1K 2K 3K 1Q A = 1 Micron N = NA B = Buna
Contact factory for X1 37 1K 2K 3K 1Q 3Q B = 3 Micron A = Z1 (K or Q) (Standard)
specific applications. 82 3K 1Q 3Q C = 5 Micron B = Z3 (K or Q) H = EPR
(X3, X6)
17 2K 3K 1Q D = 10 Micron C = Z5 (K or Q) V = Viton ®
Boxes 4 & 5. E = 25 Micron D = Z10 (K or Q)
Z1 media not offered X2 37 3K 3Q
for use in 500 to 2000 82 3Q F = QCLQFZ1 E = Z25 (K or Q)
SUS filtration skids. 17 2K 3K 1Q 3Q G = QCLQFZ3 F = QCLQFZ1
Contact factory for X3 H = QCLQFZ5 G = QCLQFZ3 Coreless
specific applications. Z1 37 3K 3Q
and Z3 media not offered 17 1K 2K 3K 1Q J = QCLQFZ10 H = QCLQFZ5
for use in 2000 to 5000 X4 37 1K 2K 3K 1Q 3Q L = QCLQFZ25 J = QCLQFZ10
SUS filtration skids. M = QPMLZ1 L = QCLQFZ25
Contact factory for 82 3K 1Q 3Q
specific applications. 17 2K 3K 1Q P = QPMLZ3 M = QPMLZ1 Deeper
All elements are X5 37 3K 3Q R = QPMLZ5 P = QPMLZ3 Pleats
singular construction R = QPMLZ5
(no stacked elements). 82 3Q S = QPMLZ10
QPML and QCLZ 17 2K 3K 1Q 3Q T = QPMLZ25 S = QPMLZ10
coreless elements only X6 37 3K 3Q W = W T = QPMLZ25
available in the QF15 W = W
housing. X7 and X8 X7 06 3Q
only available with X8 30 3Q
options D or E.
Box 7. BOX 7 BOX 8 BOX 9 BOX 10
115 VAC power option
includes switch, 10’ Power Motor Frame Starter Control Options Dirt Alarm ®
cord, and plug. For A = 115 VAC 1.5 hp N = TEFC
1.5 hp motors only. N = None N = Cartridge in Cap (Standard)
575 will be built to (Available only with W = Washdown A = 230 VAC G = Differential Pressure Gauge
CSA standards. 109, 209, and 309) (NEMA Design B)
(E) X7 and X8 only B = 460 VAC M = MS11 Electric Cartridge
available with 230/460 N = 230/ 460 VAC C = 230 VAC (with VFD) C = Differential Pressure Gauge
VAC 3 phase motor. 3 PH.
D = 460 VAC (with VFD) with Electric Switch
Boxes 9 and10. E = 575 VA 3 PH E = 575 VAC
Motor starter control F = 575 VAC (with VFD)
option – C-series, non-
disconnect shut-off, G = 220 VAC, 50 Hz, Single Phase
“motor on” light, H = 200 VAC, 50 Hz, 3-Phase
electrical indicator
“change element”
light, and type 4x BOX 11 BOX 12 BOX 13
wash down enclosure.
VFD control Vacuum Gauge Suction Strainer Miscellaneous Options
option–same as above N = None S = Suction Strainer N = None
but with enclosed
variable frequency V = Vacuum Gauge C = Mobile
drive control and B = Continuous Bleed
larger metal P = Particle Counter
NEMA enclosure.
(Applies to M and
C in Box 10)
Box 13.
Continuous bleed
option – to eliminate
filter air buildup in
continuously
aerated systems.
Includes cap
vent port, valve,
and return line. (B)
Suction strainer
standard on
X7 and X8
Particle Counter not
available for X7 or X8.
104