Page 11 - Linde - Model code edition X-02 series product
P. 11
Model Code for HPR -02 Series - Variable Displacement Open Loop Pumps
10 11 12 13 14 15 16 17
S = _______________________
M250 X X X C C 2 X (Only when "S" is selected in pos. 17. Specify
requirement(s)). Otherwise omit "S =" FRAME SIZE
17 SPECIALS 55 75 105 105D125D 135 165 165D 210 280
X - None l l l l l l l l l l
S - Call out requirement(s) in clear text or m m m m m m m m m m
use specified code from factory.
Example: For TL2 or ETP control, specify Power Setting and Input Speed here.
16 PRODUCTION LEVEL
2 - Assigned at Factory l l l l l l l l l l
15 COUPLING - THROUGH DRIVE
X - No Coupling l l l l l l l l l l
A - SAE A 9T, 16/32 dP m m m m m m m m m -
B - SAE B 13T, 16/32 dP m m m m m m m m m m
J - SAE B-B 15T, 16/32 dP m m m m m m m m m m
C - SAE C 14T, 12/24 dP m m m m m m m - m m
G - SAE C-C 17T, 12.24 dP - - - - - m - - - -
D - SAE D 13T, 8/16 dP - - - - - m m - m m
F - SAE F 15T, 8/16 dP - - - - - - - - m m
P - ANSI 11T, 16/32 dP - - - - - - - - m -
K - ANSI 21T, 16/32 dP - - - - - - - - m -
L - ANSI 23T, 16/32 dP - - - - - - - - m -
M - ANSI 27T, 16/32 dP - - - - - - - - m m
N - ANSI 33T, 16/32 dP - - - - - - - - - m
S - Special (Specify in pos. 17) c c c c c c c c c c
Shafts are manufactured to ANSI B92.1 specifications
14 MOUNT - THROUGH DRIVE
A - SAE A, 2-Bolt Mount l l l l l l l l l l
B - SAE B, 2-Bolt Mount m m m m m m m m m m
C - SAE C, 2-Bolt Mount m m m m m m m - m m
D - SAE D, 2-Bolt Mount - - - - - m m - m m
E - SAE E, 4-Bolt Mount - - - - - - - - m m
X - With Gear Pump w/o Through Drive m m m m m m m m m m
13 MIN DISPLACEMENT
X - Standard Setting (Zero Displ.) l l l l l l l l l l
_ _ _ - Specify Setting in cc/rev if > than Zero m m m - - m m - m m
(1 cc/rev = 0.061 cir)
12 MAX DISPLACEMENT
X - Standard Setting (100% Displ.) l l l l l l l l l l
_ _ _ - Specify Setting in cc/rev if < than 100% m m m - - m m - m m
(1 cc/rev = 0.061 cir)
11 "XD" PORT CONFIGURATION Only Applicable to ETP, LEP, & LEP2 Control
P - Externally Plugged, Internal Drain Open - l l - - l l - l l
O - External Port Open, Internal Drain Plugged. - m m - - m m - m m
X - Not Applicable m m m m m m m m m m
10 COMPENSATOR (PCO)
Specify Spring Range and Setting in BAR.
K_ _ _ - 80 to <125 bar (1160 - <1800 psi) m m m m m m m m m m
L_ _ _ - 125 to <230 bar (1800 - <3335 psi) l l l l l l l l l l
M_ _ _ - 230 to <350 bar (3335 - <5075 psi) l l l l l l l l l l
N_ _ _ - 350 to 420 bar (5075 - 6090 psi) m m m m m m m m m m
X - Not Applicable m m m m m m m m m m