Model Code for HMR -02 Series - Regulated Displacement Motor
12 13 14 15 16 17 18 19 20 21
S = _____________________________
065 H 10 25 H X A X 2 X (Only when "S" is selected in pos. 21. Specify
requirement(s)). Otherwise omit "S =" FRAME SIZE
21 SPECIALS 55 75 105 135 165 210 280
X - None l l l l l l l
S - Call out requirement(s) in clear text or c c c c c c c
use specified code from factory.
20 PRODUCTION LEVEL l l l l l l l
2 - Assigned at Factory
19 ADDITIONS
X - None l l l l l l l
P - Speed Pick-Up - c c c - c c
T - Counterbalance Valve (Track) - m m m - m m
W -Counterbalance Valve (Wheel) - m m m - m m
18 PORT ORIENTATION
A - Radial (Side) l l l l - l l
B - Axial (Rear) - m* m* m* l - -
17 RELIEF VALVE
X - Without Crossover Relief l l l l l l l
bar (psi)
Std. Setting for High P - Plugged crossover relief cavity - m m m m - -
210 (3045)
Pressure Crossover
230 (3335)
Relief Valve D - Deceleration Valve for CW Rotation - m m m m - -
250 (3625)
(Adjustment Range: 270 (3915) E - Deceleration Valve for CCW Rotation - m m m m - -
80 to 420 bar (1160 to
350 (5075) R_ _ _ - Specify setting in bar - m m m m c c
6000 psi))
420 (6090)
(COR Package for 210 and 280 Frame Sizes is Bolt On style.)
Specify setting in BAR. (1 bar = 14.5 psi)
16 SHUTTLE
(no longer used in new Production) N - Old Style Fluted Spool - - - - - - -
B - Blocked Fluted Spool m m m m m m m
H - New Style High Flow l l l l l l l
D - High Flow Dampened m m m m m m m
P - Blocked New Style High Flow m m m m m m m
X - (applies when "P" is selected in Pos. 13) m m m m m m m
15 FLOW ORIFICE
18 (Enter 10 x Orifice Size) m m m m m m m
20 m m m m m m m
25 l l l l l l l
B - (applies when Blocking Disc is used) m m m m m m m
X - (applies when "P" is selected in Pos. 13) m m m m m m m
14 PURGE VALVE
05 (Enter Setting in Bar) m m m m m m m
10 l l l l l l l
14 m m m m m m m
20 m m m m m m m
25 m m m m m m m
X - (applies when "B" or "P" is selected in Pos. 13) m m m m m m m
13 PURGE VALVE
(no longer used in new Production) C - Closed Loop Relief Valve - - - - - - -
O - Open Loop Purge Valve m m m m m m m
H - High Flow Closed Loop Relief Valve l l l l l l l
B - Blocked Purge Valve m m m m m m m
P - Plain, without Purge and Shuttle Valve m m m m m - -
12 MIN DISPLACEMENT
_ _ _ - Specify Setting in cc/rev l l l l l l l
(1 cc/rev = 0.061 cir)
11 MAX DISPLACEMENT
X - Standard Setting (100% Displ.) l l l l l l l
_ _ _ - Specify Setting in cc/rev if < than 100% m m m m m m m
(1 cc/rev = 0.061 cir)