Page 6 - Proportion-Air - MM1/MM2 Control Valves
P. 6
MM SERIES ORDERING INFORMATION
MM 2 D B N E E
Series Type Mount Manifold Thread Input Monitor
Type Material Type Signal Signal
Range Range
1 = Open Loop
2 = Closed Loop B = Brass
X = No Monitor Signal
C = 4 to 20 mADC Sinking
D = DIN Rail Mount (Ports on Face) H = Manifold Mount (No Threads) E = 0 to 10 VDC
M = Manifold Mount (Ports on Bottom) N = NPT K = 0 to 5 VDC 1
P = Panel Mount (Ports on Face) P = BSPP (Non-Standard) S = 4 to 20 mADC Sourcing
V = 1 to 5 VDC 1
N
1 Only available if the same Input = 0% Pressure Starts Below Atmosphere
P =
Signal Range is selected 0% Pressure Starts Above Atmosphere
Max IN Pressure: 200 psig (20.6 bar) E = 0 to 10 VDC 0% Pressure Starts at Zero
Z =
Max OUT Pressure: 175 psig (12 bar) = 4 to 20 mADC
Typical Accuracy: +/- 0.2% (Full Scale of sensor) K = 0 to 5 VDC
Regulators: none V = 1 to 5 VDC
Power Supply: 15 VDC, 24 VDC, 12 VDC (Option P1)
MM SERIES ACCESSORIES MM SERIES SUB BASE MANIFOLD
Power Connector Mounting Kits Station Plug
H14612 DIN Rail DRMKT-01 H316
Panel Mount PMK-MM
Manifold Mount See HARDWARE KIT
PROPORTION-AIR ▪ 317-335-2602